Induction machine with squirrel cage
Resistances and stray inductances of the machine refer to an
m-phase stator. The symmetry of the stator and rotor
is assumed. The machine models take the following loss effects into
account:
- heat losses in the temperature dependent stator winding
resistances
- heat losses in the temperature dependent cage resistances
- friction losses
- core losses (only eddy current losses, no hysteresis
losses)
- stray load losses
See also
IM_SlipRing,